{"id":7730,"date":"2025-12-11T12:32:46","date_gmt":"2025-12-11T17:32:46","guid":{"rendered":"https:\/\/randpc.com\/blog\/?p=7730"},"modified":"2025-12-11T13:44:18","modified_gmt":"2025-12-11T18:44:18","slug":"fisp-cycle-10-reports","status":"publish","type":"post","link":"https:\/\/m.randpc.com\/blog\/fisp-cycle-10-reports\/","title":{"rendered":"Inside DOB&#8217;s Review of FISP Reports: What Owners Should Know for Cycle 10"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7727 \" src=\"https:\/\/randpc.com\/blog\/wp-content\/uploads\/Qewi-doing-inspectionedit-boom-lift-sweiss-w-485x364.jpg\" alt=\"Facade Inspection Safety Program (FISP) hand-on inspection by boom lift\" width=\"652\" height=\"489\" srcset=\"https:\/\/m.randpc.com\/blog\/wp-content\/uploads\/Qewi-doing-inspectionedit-boom-lift-sweiss-w-485x364.jpg 485w, https:\/\/m.randpc.com\/blog\/wp-content\/uploads\/Qewi-doing-inspectionedit-boom-lift-sweiss-w-300x225.jpg 300w, https:\/\/m.randpc.com\/blog\/wp-content\/uploads\/Qewi-doing-inspectionedit-boom-lift-sweiss-w-150x113.jpg 150w, https:\/\/m.randpc.com\/blog\/wp-content\/uploads\/Qewi-doing-inspectionedit-boom-lift-sweiss-w-768x576.jpg 768w, https:\/\/m.randpc.com\/blog\/wp-content\/uploads\/Qewi-doing-inspectionedit-boom-lift-sweiss-w-360x270.jpg 360w, https:\/\/m.randpc.com\/blog\/wp-content\/uploads\/Qewi-doing-inspectionedit-boom-lift-sweiss-w.jpg 800w\" sizes=\"auto, (max-width: 652px) 100vw, 652px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: 400;\">For owners, boards, and property managers planning for <a href=\"http:\/\/www.randpc.com\/fisp\">Facade Inspection Safety Program<\/a> (FISP) Cycle 10, it helps to understand which aspects of a report tend to receive the closest review from the Department of Buildings (DOB). FISP filings are not just about describing what\u2019s happening on the facade; DOB reviewers look closely at how the QEWI performed the inspection, how conditions are documented, and how the proposed repairs follow from those observations.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Across the city, that attention is most evident in how closely DOB reviews inspection methods, access, and decorative materials like terra cotta and stone. For owners and boards, that translates into a FISP process that benefits from careful planning, thorough documentation, and close coordination with the inspection and design team.<\/span><\/p>\n<h2><strong>Key Areas of Focus in QEWI Reports<\/strong><\/h2>\n<p><span style=\"font-weight: 400;\">DOB reviewers look not only at the final condition rating (Safe, SWARMP, or Unsafe), but at the information that supports those ratings and the associated repair program recommendations.<\/span><\/p>\n<p><strong>Detailed comments on inspection methods, access, and scope<\/strong><\/p>\n<p><span style=\"font-weight: 400;\">Report reviews often include comments and questions about:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">How the facade was accessed.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The methods used to perform the inspection.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The scope of proposed repairs.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Any follow-up work referenced in the report.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Because RAND files a large volume of FISP reports, we see these themes frequently and structure our standard documentation to address DOB\u2019s expectations upfront.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><strong>E<\/strong><strong>mphasis on procedural and documentation detail<\/strong><\/p>\n<p><span style=\"font-weight: 400;\">Reports are evaluated on how thoroughly the QEWI documents:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Areas of access and the methods used (drops, scaffold, rope access, boom lift, etc.).<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The extent and locations of hands-on inspection.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Observed facade conditions.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">How observed defects relate to the proposed repair plan.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">DOB may also perform site re-inspections when filings prompt questions about conditions or completed work, using these visits to verify that reported information aligns with actually exists at the site.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">For owners, this level of review means a FISP filing benefits from:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Detailed documentation at the outset.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Prompt responses to any follow-up questions from DOB reviewers.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Close coordination between the QEWI, the owner, management, and the contractor.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Decorative Facades: Terra Cotta, Stone, and Cast Elements<\/strong><\/p>\n<p><span style=\"font-weight: 400;\">Perhaps the greatest scrutiny in the DOB review is directed at decorative facade elements, particularly on buildings with materials that have been associated with prior failures.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Materials that often draw detailed attention include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Terra cotta<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Natural stone<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Cast stone<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Cast iron<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: 400;\">RAND sees the following expectations in FISP filings involving these components:<\/span><\/p>\n<p><strong>Hands-on sounding<\/strong><\/p>\n<p><span style=\"font-weight: 400;\">For these materials, visual observation alone is not considered sufficient. A representative sample of decorative units, at a minimum, must be sounded as part of the hands-on inspection to verify how pervasive the observed defects are and whether sufficient sound material remains to make the decorative segment salvageable.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Documentation of each defect<\/strong><\/p>\n<p><span style=\"font-weight: 400;\">FISP reports are expected to include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Clear photographs of each defect.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Elevation drawings locating every cracked, spalled, displaced, or otherwise compromised piece.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Justification of repair vs. replacement, especially for terra cotta<\/strong><\/p>\n<p><span style=\"font-weight: 400;\">DOB often favors full replacement of deteriorated terra cotta units rather than patching or partial repair. When repairs are proposed in lieu of replacement, reviewers look for a clear explanation and supporting documentation showing that the repair approach and methods are appropriate and durable. Reports should explain:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Why repair was chosen instead of replacement.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">A step-by-step description of how repairs were performed.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Which repair materials and mortars were used.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Progress photos documenting repairs as they were performed.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">DOB\u2019s approach to decorative facades places particular emphasis on terra cotta repairs - how durable they are, how they were performed, and how they\u2019re documented. For owners with decorative facades, that typically means:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">More extensive hands-on work.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Additional design and documentation effort.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Closer review of any proposed repair strategy that does not involve full replacement.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2><strong>What This Means for Owners and Managers<\/strong><\/h2>\n<p><span style=\"font-weight: 400;\">For owners and property managers, understanding where DOB focuses its review can help you more effectively plan inspections, repairs, and FISP filings.<\/span><\/p>\n<p><strong>Expect thorough inspections and robust documentation.<\/strong><span style=\"font-weight: 400;\"><br \/>\n<\/span><span style=\"font-weight: 400;\">Hands-on work, sounding of decorative elements, detailed photos, and elevation mark-ups need to be considered standard expectations, especially for buildings with terra cotta, stone, or cast components.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><strong>Build time into your schedule for comments and clarifications.<\/strong><span style=\"font-weight: 400;\"><br \/>\n<\/span><span style=\"font-weight: 400;\">Even well-prepared reports may be returned with questions. Allowing time for comment response and re-review supports realistic filing and repair timelines.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><strong>Coordinate early with your QEWI.<\/strong><span style=\"font-weight: 400;\"><br \/>\n<\/span><span style=\"font-weight: 400;\">Talking through the inspection plan, filing approach, and possible repairs up front helps ensure your report reflects the aspects of FISP that DOB is most likely to focus on.<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><span style=\"font-weight: 400;\"><br \/>\n<\/span><strong>Work with an experienced QEWI and support team.<\/strong><span style=\"font-weight: 400;\"><br \/>\n<\/span><span style=\"font-weight: 400;\">With DOB reviewing both the technical findings and the inspection process, it is important that your QEWI:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Understands where DOB is focusing its attention in the current cycle.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Is prepared to support inspection methods and repair decisions with clear documentation.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Knows how to present terra cotta and other decorative repairs in a way that speaks to DOB\u2019s expectations.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: 400;\">At RAND, our QEWIs and facade team incorporate these priorities into how we plan inspections, document conditions, and prepare filings. If you\u2019d like to review your building\u2019s FISP obligations or discuss how these focus areas may affect your next report or repair program, we\u2019re here as a resource.<\/span><\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p><em>RAND Engineering &amp; Architecture, DPC has been serving New York\u2019s building community for nearly 40 years. Founded in 1987, our firm designs and administers programs for the repair, upgrade, restoration, and adaptive reuse of residential, commercial, institutional, and retail properties.<\/em><\/p>\n<p><em>Our expertise includes exterior envelope repair - with a particular focus on FISP - parapet inspections and repair programs, window and door replacement, heating, plumbing, and electrical upgrades, garage inspections and repair programs, architectural design and ADA compliance, feasibility studies and plan reviews, structural engineering, forensic surveys, benchmarking, energy audits, and retro-commissioning, green roofs, and historic restoration.<\/em><\/p>\n<p><em>RAND also has dedicated groups for Building Design, Industrial Rope Access, Drone Services, Infrared Surveys, and 3D Laser Scanning. We also have a Code &amp; Zoning Compliance Team and are an accredited Special Inspections Agency.<\/em><\/p>\n<p><em>To learn more, please visit<a href=\"https:\/\/www.randpc.com\"> randpc.com<\/a>.<\/em><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>DOB is taking a closer look at how QEWIs inspect facades, document conditions, and justify repair strategies in Cycle 10. Reports involving decorative materials like terra cotta and stone are receiving especially detailed review, making it important for owners and managers to understand DOB\u2019s focus and prepare stronger filings.<\/p>\n <span class=\"read-more\"><a href=\"https:\/\/m.randpc.com\/blog\/fisp-cycle-10-reports\/\" class=\"more-link\" title=\"Read More\"><strong>Read more<\/strong><\/a><\/span>","protected":false},"author":13,"featured_media":7727,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[882,566,413,717,18,33,1],"tags":[305,113,892,371,384,35],"class_list":["post-7730","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-building-envelope","category-exterior-walls","category-facade-inspection-safety-program-fisp","category-facade-inspections","category-facades","category-terra-cotta","category-uncategorized","tag-facade-inspection-safety-program","tag-fisp","tag-fisp-reports","tag-rand","tag-rand-engineering-architecture","tag-terra-cotta-2"],"_links":{"self":[{"href":"https:\/\/m.randpc.com\/blog\/wp-json\/wp\/v2\/posts\/7730","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/m.randpc.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/m.randpc.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/m.randpc.com\/blog\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/m.randpc.com\/blog\/wp-json\/wp\/v2\/comments?post=7730"}],"version-history":[{"count":12,"href":"https:\/\/m.randpc.com\/blog\/wp-json\/wp\/v2\/posts\/7730\/revisions"}],"predecessor-version":[{"id":7749,"href":"https:\/\/m.randpc.com\/blog\/wp-json\/wp\/v2\/posts\/7730\/revisions\/7749"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/m.randpc.com\/blog\/wp-json\/wp\/v2\/media\/7727"}],"wp:attachment":[{"href":"https:\/\/m.randpc.com\/blog\/wp-json\/wp\/v2\/media?parent=7730"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/m.randpc.com\/blog\/wp-json\/wp\/v2\/categories?post=7730"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/m.randpc.com\/blog\/wp-json\/wp\/v2\/tags?post=7730"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}